{"product_id":"10w-explosion-proof-emergency-light-oil-gas-sites","title":"10W Explosion Proof Emergency Light for Oil and Gas Sites","description":"\u003cstyle\u003e\n.p-wrapper{font-family:Inter,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,sans-serif;max-width:1000px;margin:0 auto;color:#333;line-height:1.6;padding:20px}\n.p-header{border-bottom:3px solid #1a73e8;padding-bottom:15px;margin-bottom:25px}\n.p-header h1{font-size:26px;color:#111;margin:0 0 10px;font-weight:800}\n.p-badge-container{display:flex;gap:10px;flex-wrap:wrap}\n.p-badge{background:#e8f0fe;color:#1a73e8;padding:5px 12px;border-radius:4px;font-size:12px;font-weight:700;text-transform:uppercase;border:1px solid #d2e3fc}\n.p-intro{font-size:15px;color:#555;margin:24px 0}\n.p-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:20px;margin:30px 0}\n.p-feature-card{background:#fff;padding:20px;border-radius:8px;border:1px solid #eee;text-align:center;box-shadow:0 4px 6px rgba(0,0,0,.03)}\n.p-feature-card h3{font-size:17px;margin:0 0 10px;color:#1a73e8}\n.p-feature-card p{font-size:14px;margin:0;color:#666}\n.p-section-title{font-size:20px;font-weight:700;border-left:5px solid #1a73e8;padding-left:15px;margin:40px 0 20px;color:#2c3e50}\n.p-specs-table{width:100%;border-collapse:collapse;margin-bottom:30px}\n.p-specs-table tr:nth-child(even){background:#f9f9f9}\n.p-specs-table td{padding:12px 15px;border:1px solid #eee;font-size:14px;vertical-align:top}\n.p-specs-table td:first-child{width:35%;font-weight:700;color:#444;background:#f4f4f4}\n.p-benefits-list{list-style:none;padding:0;display:grid;grid-template-columns:1fr 1fr;gap:15px}\n.p-benefits-list li{position:relative;padding-left:25px;font-size:15px}\n.p-benefits-list li:before{content:\"✓\";position:absolute;left:0;color:#1a73e8;font-weight:bold}\n.p-applications{font-size:15px;color:#555}\n.p-note{font-size:13px;color:#666;background:#fafafa;border:1px solid #eee;border-radius:6px;padding:14px}\n.p-cta{margin-top:35px;padding:26px;background:#f5f9ff;border:1px solid #d2e3fc;border-radius:8px;text-align:center}\n.p-cta h2{font-size:21px;margin:0 0 8px;color:#1f2937}\n.p-cta p{font-size:14px;color:#555;margin:0}\n@media(max-width:600px){.p-wrapper{padding:15px}.p-benefits-list{grid-template-columns:1fr}.p-header h1{font-size:22px}}\n\u003c\/style\u003e\n\n\u003cdiv class=\"p-wrapper\"\u003e\n  \u003cdiv class=\"p-header\"\u003e\n    \u003ch1\u003e10W Explosion Proof Emergency Light for Oil and Gas Sites\u003c\/h1\u003e\n    \u003cdiv class=\"p-badge-container\"\u003e\n      \u003cspan class=\"p-badge\"\u003e10W \/ 900 Lumens\u003c\/span\u003e\n      \u003cspan class=\"p-badge\"\u003e3-Hour Emergency\u003c\/span\u003e\n      \u003cspan class=\"p-badge\"\u003eClass I Division 1\u003c\/span\u003e\n      \u003cspan class=\"p-badge\"\u003eIP66 \/ NEMA 4X\u003c\/span\u003e\n      \u003cspan class=\"p-badge\"\u003e120-277V\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cp class=\"p-intro\"\u003e\n    The Eco Bright Light Explosion Proof Emergency Light provides reliable backup illumination for hazardous industrial environments. Its dual adjustable LED heads deliver up to 900 lumens of 5000K light for approximately three hours, helping maintain visibility along evacuation routes, process areas and critical work zones during a power failure.\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"p-grid\"\u003e\n    \u003cdiv class=\"p-feature-card\"\u003e\n      \u003ch3\u003e3-Hour Emergency Lighting\u003c\/h3\u003e\n      \u003cp\u003eProvides extended backup illumination during power outages, emergencies and evacuation procedures.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"p-feature-card\"\u003e\n      \u003ch3\u003eDual Adjustable LED Heads\u003c\/h3\u003e\n      \u003cp\u003eEach spotlight can be aimed horizontally and vertically to illuminate exits, equipment and travel paths.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"p-feature-card\"\u003e\n      \u003ch3\u003eC1D1 Hazardous Location\u003c\/h3\u003e\n      \u003cp\u003eDesigned for classified industrial locations containing flammable gases, vapors, combustible dust or fibers.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"p-feature-card\"\u003e\n      \u003ch3\u003eIP66 and NEMA 4X\u003c\/h3\u003e\n      \u003cp\u003eThe sealed corrosion-resistant enclosure supports wet, dusty and demanding indoor or outdoor locations.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n\n  \u003ctable class=\"p-specs-table\"\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBrand\u003c\/td\u003e\n      \u003ctd\u003eEco Bright Light\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eDual-Head Explosion Proof LED Emergency Light\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Power\u003c\/td\u003e\n      \u003ctd\u003e10W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Lumen Output\u003c\/td\u003e\n      \u003ctd\u003eUp to 900 Lumens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Runtime\u003c\/td\u003e\n      \u003ctd\u003eApproximately 3 Hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eColor Temperature\u003c\/td\u003e\n      \u003ctd\u003e5000K Daylight\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd\u003e120-277V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLight Heads\u003c\/td\u003e\n      \u003ctd\u003eTwo High-Output Adjustable LED Spotlights\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHead Adjustment\u003c\/td\u003e\n      \u003ctd\u003eHorizontal and Vertical Adjustment from 0° to 180°\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBeam Angle Options\u003c\/td\u003e\n      \u003ctd\u003e90° or 120°\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHazardous Location Rating\u003c\/td\u003e\n      \u003ctd\u003eClass I, Division 1, Groups C and D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAdditional Gas Classification\u003c\/td\u003e\n      \u003ctd\u003eClass I, Division 2, Groups A, B, C and D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCombustible Dust Classification\u003c\/td\u003e\n      \u003ctd\u003eClass II, Division 1, Groups E, F and G\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAdditional Dust Classification\u003c\/td\u003e\n      \u003ctd\u003eClass II, Division 2, Groups F and G\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFiber and Flyings Classification\u003c\/td\u003e\n      \u003ctd\u003eClass III Hazardous Locations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIngress Protection\u003c\/td\u003e\n      \u003ctd\u003eIP66 Wet Location Rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd\u003eNEMA 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eImpact Resistance\u003c\/td\u003e\n      \u003ctd\u003eIK10\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Driver\u003c\/td\u003e\n      \u003ctd\u003ePHENIX Emergency Backup Driver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eA360 Die-Cast Aluminum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHardware\u003c\/td\u003e\n      \u003ctd\u003eCorrosion-Resistant Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLens Material\u003c\/td\u003e\n      \u003ctd\u003eTempered Glass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Width\u003c\/td\u003e\n      \u003ctd\u003eApproximately 12 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Height\u003c\/td\u003e\n      \u003ctd\u003eApproximately 12.6 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFixture Depth\u003c\/td\u003e\n      \u003ctd\u003eApproximately 6.5 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Dimensions\u003c\/td\u003e\n      \u003ctd\u003eApproximately 11 × 6.7 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Hole Spacing\u003c\/td\u003e\n      \u003ctd\u003eApproximately 9.88 in Center to Center\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eWall Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConduit Entry\u003c\/td\u003e\n      \u003ctd\u003eThree 3\/4-Inch NPT Conduit Hubs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-4°F to 140°F \/ -20°C to 60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Lifetime\u003c\/td\u003e\n      \u003ctd\u003eUp to 50,000 Hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStandards\u003c\/td\u003e\n      \u003ctd\u003eUL 844, UL 924, UL 1598, UL 1598A and UL 8750\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCertification\u003c\/td\u003e\n      \u003ctd\u003eETL Listed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWarranty\u003c\/td\u003e\n      \u003ctd\u003e5-Year Limited Warranty\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eEmergency Lighting for Classified Areas\u003c\/h2\u003e\n\n  \u003cul class=\"p-benefits-list\"\u003e\n    \u003cli\u003eProvides up to three hours of illumination after normal power is lost.\u003c\/li\u003e\n    \u003cli\u003eDual adjustable heads direct light toward exits and critical equipment.\u003c\/li\u003e\n    \u003cli\u003eClass I Division 1 rating supports demanding oil and gas applications.\u003c\/li\u003e\n    \u003cli\u003eClass II ratings support locations containing combustible dust.\u003c\/li\u003e\n    \u003cli\u003eIP66 enclosure protects against dust and powerful water exposure.\u003c\/li\u003e\n    \u003cli\u003eNEMA 4X construction supports corrosive industrial environments.\u003c\/li\u003e\n    \u003cli\u003eIK10 impact resistance helps protect the fixture from physical damage.\u003c\/li\u003e\n    \u003cli\u003e50,000-hour rated life helps reduce inspection and replacement costs.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eDual Adjustable Emergency Spotlights\u003c\/h2\u003e\n\n  \u003cp class=\"p-applications\"\u003e\n    The two LED heads can be rotated and aimed independently to illuminate evacuation routes, doors, stairways, valves, control equipment and other high-priority areas. Select the appropriate 90° or 120° optical distribution based on the required coverage and mounting distance.\n  \u003c\/p\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eHazardous Location Wall Installation\u003c\/h2\u003e\n\n  \u003cp class=\"p-applications\"\u003e\n    Secure the fixture to a suitable wall using the designated mounting holes. Route the branch-circuit conductors through one of the 3\/4-inch NPT conduit hubs, connect line, neutral and ground, install the required seals and gaskets, and then adjust both LED heads toward the required emergency coverage area.\n  \u003c\/p\u003e\n\n  \u003cp class=\"p-note\"\u003e\n    Hazardous-location performance depends on the complete installation, including approved conduit, sealing fittings, chemical sealant, gaskets, fasteners and wiring methods. Installation and testing must be completed by qualified personnel according to the supplied instructions and applicable electrical and life-safety codes.\n  \u003c\/p\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eOil, Gas and Industrial Safety Applications\u003c\/h2\u003e\n\n  \u003cp class=\"p-applications\"\u003e\n    Ideal for oil and gas refineries, drilling facilities, petrochemical plants, chemical processing areas, marine facilities, offshore platforms, wastewater plants, fuel storage locations, paint facilities, manufacturing plants and classified evacuation routes.\n    \u003cbr\u003e\u003cbr\u003e\n    \u003cstrong\u003eExplosion Proof Emergency Light | C1D1 Emergency Lighting | Hazardous Location Emergency Light | Oil and Gas Emergency Lighting | Refinery Safety Lighting | Chemical Plant Emergency Light | IP66 Emergency Light | NEMA 4X Lighting | Industrial Backup Lighting | Class I Division 1 Light\u003c\/strong\u003e\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"p-cta\"\u003e\n    \u003ch2\u003eMaintain Critical Visibility During Power Failures\u003c\/h2\u003e\n    \u003cp\u003eChoose Eco Bright Light for three-hour emergency operation, dual adjustable LED heads, C1D1 hazardous-location performance and rugged IP66 protection.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003ePackage Information\u003c\/h2\u003e\n\n  \u003ctable class=\"p-specs-table\"\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePackage Size\u003c\/td\u003e\n      \u003ctd\u003e22 × 22 × 8 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePack Quantity\u003c\/td\u003e\n      \u003ctd\u003e1 Emergency Light\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePackage Weight\u003c\/td\u003e\n      \u003ctd\u003e24 lbs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e","brand":"Eco Bright LED","offers":[{"title":"Default Title","offer_id":48541291380930,"sku":"EBL-35330","price":842.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0746\/3587\/0402\/files\/dual-head-10-w-explosion-proof-emergency-light.webp?v=1789555434","url":"https:\/\/www.ecobrightled.com\/products\/10w-explosion-proof-emergency-light-oil-gas-sites","provider":"Eco Bright LED","version":"1.0","type":"link"}