{"product_id":"18w-waterproof-emergency-driver-canopy-lighting","title":"18W Waterproof LED Emergency Driver for Outdoor Lighting","description":"\u003cstyle\u003e\n.p-wrapper{font-family:Inter,-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,sans-serif;max-width:1000px;margin:0 auto;color:#333;line-height:1.6;padding:20px}\n.p-header{border-bottom:3px solid #1a73e8;padding-bottom:15px;margin-bottom:25px}\n.p-header h1{font-size:26px;color:#111;margin:0 0 10px;font-weight:800}\n.p-badge-container{display:flex;gap:10px;flex-wrap:wrap}\n.p-badge{background:#e8f0fe;color:#1a73e8;padding:5px 12px;border-radius:4px;font-size:12px;font-weight:700;text-transform:uppercase;border:1px solid #d2e3fc}\n.p-intro{font-size:15px;color:#555;margin:24px 0}\n.p-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:20px;margin:30px 0}\n.p-feature-card{background:#fff;padding:20px;border-radius:8px;border:1px solid #eee;text-align:center;box-shadow:0 4px 6px rgba(0,0,0,.03)}\n.p-feature-card h3{font-size:17px;margin:0 0 10px;color:#1a73e8}\n.p-feature-card p{font-size:14px;margin:0;color:#666}\n.p-section-title{font-size:20px;font-weight:700;border-left:5px solid #1a73e8;padding-left:15px;margin:40px 0 20px;color:#2c3e50}\n.p-specs-table{width:100%;border-collapse:collapse;margin-bottom:30px}\n.p-specs-table tr:nth-child(even){background:#f9f9f9}\n.p-specs-table td{padding:12px 15px;border:1px solid #eee;font-size:14px;vertical-align:top}\n.p-specs-table td:first-child{width:35%;font-weight:700;color:#444;background:#f4f4f4}\n.p-benefits-list{list-style:none;padding:0;display:grid;grid-template-columns:1fr 1fr;gap:15px}\n.p-benefits-list li{position:relative;padding-left:25px;font-size:15px}\n.p-benefits-list li:before{content:\"✓\";position:absolute;left:0;color:#1a73e8;font-weight:bold}\n.p-applications{font-size:15px;color:#555}\n.p-note{font-size:13px;color:#666;background:#fafafa;border:1px solid #eee;border-radius:6px;padding:14px}\n.p-cta{margin-top:35px;padding:26px;background:#f5f9ff;border:1px solid #d2e3fc;border-radius:8px;text-align:center}\n.p-cta h2{font-size:21px;margin:0 0 8px;color:#1f2937}\n.p-cta p{font-size:14px;color:#555;margin:0}\n@media(max-width:600px){.p-wrapper{padding:15px}.p-benefits-list{grid-template-columns:1fr}.p-header h1{font-size:22px}}\n\u003c\/style\u003e\n\n\u003cdiv class=\"p-wrapper\"\u003e\n  \u003cdiv class=\"p-header\"\u003e\n    \u003ch1\u003e18W Waterproof LED Emergency Driver for Canopy Lighting\u003c\/h1\u003e\n    \u003cdiv class=\"p-badge-container\"\u003e\n      \u003cspan class=\"p-badge\"\u003e18W Constant Output\u003c\/span\u003e\n      \u003cspan class=\"p-badge\"\u003e90-Minute Backup\u003c\/span\u003e\n      \u003cspan class=\"p-badge\"\u003e100-347V Input\u003c\/span\u003e\n      \u003cspan class=\"p-badge\"\u003e170V DC Output\u003c\/span\u003e\n      \u003cspan class=\"p-badge\"\u003eAutomatic Self-Test\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cp class=\"p-intro\"\u003e\n    The Eco Bright Light 18W Waterproof Junction Box LED Emergency Driver adds dependable battery-powered operation to compatible commercial LED fixtures. Its integrated junction box, rechargeable battery and self-diagnostic controls automatically provide constant 18W emergency output for at least 90 minutes when normal AC power is interrupted.\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"p-grid\"\u003e\n    \u003cdiv class=\"p-feature-card\"\u003e\n      \u003ch3\u003e18W Emergency Output\u003c\/h3\u003e\n      \u003cp\u003eProvides higher emergency illumination for compatible canopy lights, wall packs and commercial LED fixtures.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"p-feature-card\"\u003e\n      \u003ch3\u003e90-Minute Operation\u003c\/h3\u003e\n      \u003cp\u003eAutomatically maintains essential lighting for at least 90 minutes after normal utility power fails.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"p-feature-card\"\u003e\n      \u003ch3\u003eIntegrated Junction Box\u003c\/h3\u003e\n      \u003cp\u003eThe enclosed driver, battery and wiring compartment simplify fixture installation and component protection.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"p-feature-card\"\u003e\n      \u003ch3\u003eAutomatic Self-Testing\u003c\/h3\u003e\n      \u003cp\u003eIntegrated diagnostics perform scheduled monthly and annual tests to verify emergency performance.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n\n  \u003ctable class=\"p-specs-table\"\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBrand\u003c\/td\u003e\n      \u003ctd\u003eEco Bright Light\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eWaterproof Junction Box LED Emergency Backup Driver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Output Power\u003c\/td\u003e\n      \u003ctd\u003eConstant 18W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd\u003e100-347V AC, 50\/60Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n      \u003ctd\u003e200mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Recharge Power\u003c\/td\u003e\n      \u003ctd\u003e12W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Output Voltage\u003c\/td\u003e\n      \u003ctd\u003e170V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Output\u003c\/td\u003e\n      \u003ctd\u003e12V DC, 0.17A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Runtime\u003c\/td\u003e\n      \u003ctd\u003eMinimum 90 Minutes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecharge Time\u003c\/td\u003e\n      \u003ctd\u003eApproximately 24 Hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBattery Type\u003c\/td\u003e\n      \u003ctd\u003eIntegrated Rechargeable Lithium-Ion Battery\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBattery Construction\u003c\/td\u003e\n      \u003ctd\u003eSealed, Maintenance-Free and Not Field Replaceable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBattery Protection\u003c\/td\u003e\n      \u003ctd\u003eOver-Temperature Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Lumen Calculation\u003c\/td\u003e\n      \u003ctd\u003eFixture Efficacy × 18W Emergency Output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Lumen Example\u003c\/td\u003e\n      \u003ctd\u003eApproximately 1,800 Lumens with a 100 lm\/W LED Fixture\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFixtures Above 18W\u003c\/td\u003e\n      \u003ctd\u003eRequire a Compatible 0-10V Dimmable LED Driver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Dimmed Load\u003c\/td\u003e\n      \u003ctd\u003eMust Be Reduced to 18W or Less During Emergency Operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimming Control Voltage\u003c\/td\u003e\n      \u003ctd\u003eEmergency DIM Input Must Remain Below 20V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Activation\u003c\/td\u003e\n      \u003ctd\u003eAutomatic Transfer When Normal AC Power Fails\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMonthly Self-Test\u003c\/td\u003e\n      \u003ctd\u003eAutomatic 30-Second Discharge Test Every 30 Days\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnnual Self-Test\u003c\/td\u003e\n      \u003ctd\u003eAutomatic 90-Minute Discharge Test Every 365 Days\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManual Short Test\u003c\/td\u003e\n      \u003ctd\u003ePress the Test Switch Once for a 30-Second Test\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManual Full Test\u003c\/td\u003e\n      \u003ctd\u003ePress the Test Switch Twice in Sequence for a Full Discharge Test\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCharging Indicator\u003c\/td\u003e\n      \u003ctd\u003eSteady Indicator During Normal Charging\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEmergency Test Indicator\u003c\/td\u003e\n      \u003ctd\u003eSlow Flashing During Testing or Emergency Operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFault Indicator\u003c\/td\u003e\n      \u003ctd\u003eRapid Flashing or No Indicator During Abnormal Operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eJunction Box Dimensions\u003c\/td\u003e\n      \u003ctd\u003eApproximately 7.95 × 4.96 × 3.28 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Mounting Length\u003c\/td\u003e\n      \u003ctd\u003eApproximately 9.22 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Mounting Width\u003c\/td\u003e\n      \u003ctd\u003eApproximately 4.97 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConduit Entries\u003c\/td\u003e\n      \u003ctd\u003e1\/2-Inch NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n      \u003ctd\u003e32°F to 122°F \/ 0°C to 50°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLocation Rating\u003c\/td\u003e\n      \u003ctd\u003eDry and Damp Indoor Locations and Compatible Plenum Spaces\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Type\u003c\/td\u003e\n      \u003ctd\u003eFactory or Field Installation in Compatible Grounded LED Fixtures\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSupported Wiring\u003c\/td\u003e\n      \u003ctd\u003eStandard Fixture, 0-10V Dimmer, AC Sensor or DC Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCompliance\u003c\/td\u003e\n      \u003ctd\u003eUL 924 and CSA C22.2 No. 141\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnergy Compliance\u003c\/td\u003e\n      \u003ctd\u003eCalifornia Energy Commission Title 20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWarranty\u003c\/td\u003e\n      \u003ctd\u003e5-Year Limited Warranty\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eIntegrated Emergency Junction Box Design\u003c\/h2\u003e\n\n  \u003cul class=\"p-benefits-list\"\u003e\n    \u003cli\u003eConstant 18W output provides predictable emergency illumination.\u003c\/li\u003e\n    \u003cli\u003eMaintains battery-powered lighting for at least 90 minutes.\u003c\/li\u003e\n    \u003cli\u003eWide 100-347V input supports commercial electrical systems.\u003c\/li\u003e\n    \u003cli\u003eIntegrated junction box protects the driver, battery and wiring.\u003c\/li\u003e\n    \u003cli\u003eMultiple conduit entries simplify commercial fixture installation.\u003c\/li\u003e\n    \u003cli\u003eAutomatic transfer activates immediately after AC power failure.\u003c\/li\u003e\n    \u003cli\u003eSelf-testing supports routine emergency-system verification.\u003c\/li\u003e\n    \u003cli\u003eFactory or field installation supports new and retrofit projects.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eFixture, Dimmer and Sensor Compatibility\u003c\/h2\u003e\n\n  \u003cp class=\"p-applications\"\u003e\n    The emergency driver connects to the AC input of the fixture's regular LED driver. Compatible wiring configurations support standard LED fixtures, 0-10V dimmers, AC occupancy sensors and DC sensors. Fixtures operating above 18W require a compatible 0-10V driver so emergency operation can reduce the connected load to 18W or less.\n  \u003c\/p\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eAutomatic Self-Diagnostics\u003c\/h2\u003e\n\n  \u003cp class=\"p-applications\"\u003e\n    The integrated self-diagnostic system performs a 30-second emergency test every 30 days and a complete 90-minute discharge test every 365 days. The visible test switch also permits manual short-duration and full-discharge testing while the indicator communicates charging, emergency and fault conditions.\n  \u003c\/p\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eInstallation and Safety Requirements\u003c\/h2\u003e\n\n  \u003cp class=\"p-applications\"\u003e\n    Connect the emergency driver to an unswitched 100-347V AC supply on the same branch circuit as the regular LED driver. Complete all fixture, dimming and sensor wiring before energizing the system. Charge the internal battery for approximately 24 hours before conducting a full-duration emergency test.\n  \u003c\/p\u003e\n\n  \u003cp class=\"p-note\"\u003e\n    The junction-box enclosure is designed to protect the internal emergency components, but the official installation instructions limit the product to grounded, UL-listed indoor fixtures rated for dry or damp locations. Do not use the unit outdoors, in hazardous locations, near gas or electric heaters or inside heated-air outlets. Installation and compatibility testing must be completed by qualified personnel.\n  \u003c\/p\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003eCommercial Emergency Lighting Applications\u003c\/h2\u003e\n\n  \u003cp class=\"p-applications\"\u003e\n    Suitable for compatible LED canopy lights, wall packs, panel lights, troffers, strip lights and other commercial fixtures used in parking structures, covered entrances, warehouses, retail facilities, schools, hospitals and institutional buildings.\n    \u003cbr\u003e\u003cbr\u003e\n    \u003cstrong\u003e18W LED Emergency Driver | Waterproof Emergency Driver | Junction Box Emergency Driver | LED Battery Backup | 90 Minute Emergency Lighting | Canopy Light Emergency Backup | Wall Pack Emergency Driver | 100-347V Emergency Driver | Self Testing Emergency Driver | UL 924 Emergency Driver\u003c\/strong\u003e\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"p-cta\"\u003e\n    \u003ch2\u003eAdd High-Output Emergency Backup to LED Fixtures\u003c\/h2\u003e\n    \u003cp\u003eChoose Eco Bright Light for constant 18W emergency output, 90-minute operation, integrated junction-box construction, universal input and automatic self-testing.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 class=\"p-section-title\"\u003ePackage Information\u003c\/h2\u003e\n\n  \u003ctable class=\"p-specs-table\"\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePackage Size\u003c\/td\u003e\n      \u003ctd\u003e18.5 × 9.84 × 11 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePack Quantity\u003c\/td\u003e\n      \u003ctd\u003e10 Emergency Backup Drivers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePackage Weight\u003c\/td\u003e\n      \u003ctd\u003e34.32 lbs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e","brand":"Eco Bright LED","offers":[{"title":"Default Title","offer_id":48545404321986,"sku":"EBL-24386","price":98.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0746\/3587\/0402\/files\/18w-waterproof-led-emergency-driver-black-unit.webp?v=1789716839","url":"https:\/\/www.ecobrightled.com\/products\/18w-waterproof-emergency-driver-canopy-lighting","provider":"Eco Bright LED","version":"1.0","type":"link"}