350+ Emergency Lumens 90-Minute Backup 100-347V Input Automatic Self-Test UL 924 Listed

The Eco Bright Light 3W LED Emergency Ceiling Light provides bright, low-profile emergency illumination for commercial hallways, offices, schools, hospitals and public buildings. When normal AC power fails, the internal battery automatically activates the LED light heads and delivers more than 350 lumens for at least 90 minutes.

350+ Emergency Lumens

High-brightness LED optics provide effective emergency illumination while operating at only 3W.

90-Minute Battery Backup

The internal rechargeable battery automatically powers the fixture when normal utility power is interrupted.

Automatic Self-Diagnostics

Monthly and annual automatic tests monitor the battery, LED load and emergency operating time.

Flexible Ceiling Installation

Spring clips and optional bar hangers support sheetrock ceilings and T-Bar suspended ceiling systems.

Technical Specifications

Brand Eco Bright Light
Product Type LED Emergency Ceiling Light
Emergency Power 3W
Emergency Light Output More Than 350 Lumens
Color Temperature 5000K
Input Voltage 100-347V AC
Input Current at 120V Approximately 0.03A
Input Current at 277V Approximately 0.01A
LED Configuration Three Integrated Adjustable Emergency LED Heads
Emergency Runtime Minimum 90 Minutes
Recharge Time Maximum 24 Hours
Battery Type Integrated Maintenance-Free Rechargeable Lithium Battery
Emergency Activation Automatic Solid-State Transfer During AC Power Failure
Monthly Self-Test Automatic 30-Second Discharge Test
Annual Self-Test Automatic 90-Minute Full-Discharge Test
Quick Manual Test Press the Test Button Once for a 5-Second Functional Test
Manual Monthly Test Hold the Test Button for 3 Seconds
Manual Annual Test Hold the Test Button for 6 Seconds
Charging Indicator Solid Red
Fully Charged Indicator Solid Green
Self-Test Indicator Flashing Green
Fault Indicator Flashing Red
Emergency Mode Indicator Indicator Off
Visible Trim Dimensions Approximately 9.19 × 5.25 in
Fixture Depth Approximately 2.56 in
Rear Housing Dimensions Approximately 13.31 × 11.50 × 1.34 in
Housing Material Injection-Molded Engineering-Grade Thermoplastic
Flame Rating 5VA Flame-Retardant Construction
Housing Finish White
Mounting Methods Spring-Mounted or Bracket-Mounted Ceiling Installation
Ceiling Compatibility Sheetrock, Drywall and T-Bar Suspended Ceilings
Operating Temperature 41°F to 122°F / 5°C to 50°C
Location Rating Indoor Damp Locations
Compliance UL 924, NFPA 101, NEC, OSHA and CEC Title 20
Warranty 5-Year Limited Warranty

Automatic Emergency Operation

  • Automatically activates when normal AC power fails.
  • Delivers more than 350 lumens in emergency mode.
  • Provides at least 90 minutes of battery operation.
  • Wide 100-347V input supports commercial electrical systems.
  • Adjustable LED heads improve directional light coverage.
  • Low-profile ceiling installation reduces visual obstruction.
  • Maintenance-free battery simplifies ongoing operation.
  • Five-year warranty supports commercial lighting projects.

Self-Diagnostic Testing

The integrated monitoring circuit automatically performs a 30-second emergency discharge test every month and a complete 90-minute test every year. During each test, the system monitors LED load performance, battery voltage and emergency runtime. A flashing red indicator identifies a battery or LED-load fault requiring inspection.

Spring or Bracket Ceiling Installation

Use the spring-fit mounting clips for sheetrock and drywall ceilings, or install the supplied bar hangers in compatible T-Bar suspended ceilings. The recessed housing keeps the emergency fixture above the ceiling plane while the compact illuminated trim remains visible below.

Disconnect AC power before installation or servicing. Connect the battery only after the fixture wiring is complete, then apply continuous unswitched AC power. Allow the battery to charge for up to 24 hours before performing the first full 90-minute emergency test.

Commercial Emergency Lighting Applications

Suitable for offices, retail stores, hospitals, healthcare facilities, schools, universities, hotels, apartment buildings, warehouses, manufacturing facilities, parking garages, corridors and other indoor commercial egress routes.

LED Emergency Ceiling Light | Recessed Emergency Light | 3W Emergency Light | 90 Minute Emergency Light | Self Testing Emergency Light | 100-347V Emergency Light | Commercial Emergency Lighting | Hallway Emergency Light | Ceiling Mounted Emergency Light | UL 924 Emergency Light

Upgrade Commercial Egress Lighting

Choose Eco Bright Light for 350+ emergency lumens, automatic self-testing, 90-minute battery backup and flexible recessed ceiling installation.

Package Information

Package Size 15 × 12 × 4 in
Pack Quantity 1 Fixture
Package Weight 2.82 lbs

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.