5W Explosion Proof LED Exit Sign for Oil and Gas Facilities
5W Explosion Proof LED Exit Sign for Oil and Gas Facilities is backordered and will ship as soon as it is back in stock.
5W Explosion Proof LED Exit Sign for Oil and Gas Facilities is backordered and will ship as soon as it is back in stock.
Description
Description
5W Explosion Proof LED Exit Sign for Oil and Gas Facilities
The Eco Bright Light Explosion Proof LED Exit Sign provides clear red emergency exit identification in hazardous industrial environments. Its edge-lit double-sided display, sealed IP66 enclosure and integrated three-hour emergency backup help maintain visible evacuation guidance in oil and gas facilities, chemical plants, pump stations, grain handling areas and offshore applications.
3-Hour Emergency Backup
The integrated emergency system keeps the EXIT display illuminated for approximately 180 minutes during a power failure.
Hazardous Location Design
Suitable for Class I Division 2 gas environments and classified combustible dust or fiber locations.
Double-Sided Edge Lighting
The red double-sided EXIT display provides high-visibility emergency guidance from multiple viewing directions.
Flexible Mounting Options
Supports pendant, wall and straight-pipe mounting for different industrial building layouts.
Technical Specifications
| Brand | Eco Bright Light |
| Product Type | Explosion Proof Edge-Lit LED Exit Sign |
| Rated Power | 5W |
| Input Voltage | 120-277V AC |
| Emergency Runtime | Approximately 3 Hours / 180 Minutes |
| Display Color | Red LED |
| Display Type | Edge-Lit EXIT Legend |
| Viewing Configuration | Double-Sided EXIT Display with 180° Viewing Configuration |
| Arrow Configuration | Dual Arrow Indicators Listed for the Current Product Configuration |
| Hazardous Gas Classification | Class I, Division 2, Groups A, B, C and D |
| Combustible Dust Classification | Class II, Division 1, Groups E, F and G |
| Additional Dust Classification | Class II, Division 2, Groups F and G |
| Fiber and Flyings Classification | Class III Hazardous Locations |
| Ingress Protection | IP66 |
| Housing Material | Aluminum |
| EXIT Sign Plate | Tempered Glass |
| Exposed Hardware | Corrosion-Resistant Stainless Steel |
| Mounting Sling | Stainless Steel |
| Emergency Battery | Integrated Sealed Battery |
| Battery Replacement | Battery Is Not Field Replaceable; Replace the Complete Unit at End of Battery Life |
| Operating Modes | Maintained or Emergency-Only Operation |
| Charging Indicator | Red, Green and Yellow Battery or Fault Status Indicators |
| Fast-Charge Status | Red Indicator for Approximately 20%-80% Battery Capacity |
| Trickle-Charge Status | Green Indicator for Approximately 80%-100% Battery Capacity |
| Low Battery or Fault Status | Yellow Indicator Below 20% Capacity or During Abnormal Operation |
| Dimming | Non-Dimmable |
| Overall Width | Approximately 18.27 in |
| Overall Height | Approximately 12.07 in |
| Overall Depth | Approximately 2.09 in |
| EXIT Plate Width | Approximately 11.08 in |
| EXIT Plate Height | Approximately 6.06 in |
| Operating Temperature | -20°C to 60°C |
| Mounting Options | Pendant Mount, Wall Mount or Straight-Pipe Mount |
| Standards | UL 844 Hazardous Locations and UL 924 Emergency Lighting |
| Listing | UL HazLoc and cULus Listed |
Dependable Hazardous Location Exit Identification
- Three-hour emergency operation supports prolonged power outages.
- Double-sided display improves visibility from opposing directions.
- Red edge-lit letters provide clear emergency exit identification.
- IP66 sealing protects against dust and powerful water exposure.
- Aluminum construction supports demanding industrial environments.
- Tempered glass provides a durable and clean architectural display.
- Stainless-steel hardware improves resistance to corrosion.
- Alternate EXIT legends and language configurations are available.
Maintained or Emergency-Only Operation
The exit sign can be configured for maintained operation, where the EXIT legend remains illuminated during normal and emergency power, or emergency-only operation, where the sign activates immediately after normal power is interrupted. When utility power is restored, the unit automatically returns to mains-powered operation.
Charging and Fault Indicators
The three-color indicator system communicates battery and operating status. Red indicates fast charging, green indicates trickle charging or high battery capacity, and yellow identifies low battery capacity or abnormal operation. The integrated switch supports startup, reset and emergency shutdown procedures.
Pendant, Wall or Pipe Mounting
Use the stainless-steel sling for pendant mounting, the supplied fixing plate for wall installation or a compatible straight pipe for rigid side mounting. Select mounting hardware and hazardous-location wiring components that match the building structure and classified environment.
The current product page and official specification sheet conflict regarding Class I Division 1 certification. This page uses the Class I Division 2 rating explicitly shown in the official specification sheet. Confirm the required hazardous-location listing and obtain the applicable certification documents before specifying the product for a C1D1 project.
Oil, Gas and Industrial Safety Applications
Ideal for oil and gas facilities, chemical and petrochemical plants, battery rooms, pump stations, grain handling areas, marine facilities, offshore platforms, industrial corridors, stairwells and emergency exits located in classified environments.
Explosion Proof Exit Sign | Hazardous Location Exit Sign | C1D2 Exit Sign | Emergency Exit Sign | Industrial Exit Sign | Oil and Gas Safety Lighting | Petrochemical Exit Sign | IP66 Exit Sign | Edge Lit Exit Sign | Three Hour Emergency Sign
Provide Clear Exit Guidance in Hazardous Environments
Choose Eco Bright Light for a red edge-lit display, three-hour emergency operation, IP66 protection and flexible industrial mounting.
Package Information
| Package Size | 20 × 13 × 4 in |
| Pack Quantity | 1 Exit Sign |
| Package Weight | 8.5 lbs |
Payment & Security